Below are the selection tables prepared for PR, PRS, and PAR series boilers compatible with FBR natural gas burners, FBR diesel burners, and FBR dual-fuel burner models. For each boiler model, the appropriate FBR natural gas burner, FBR diesel burner, or FBR dual-fuel burner has been clearly indicated in the tables, allowing for an accurate burner-boiler match without the need for additional technical calculations.
For more technical information and product details, you may visit the official website of the FBR manufacturer. For the most suitable burner selection for your project, as well as technical support and inquiries, please feel free to contact us.
Looking for the perfect burner for your system? FBR burner models open up new possibilities for your business. Click the link and choose your ideal model today!
❗Brülör eşleşme tabloları yalnızca masaüstü cihazlarda görüntülenebilmektedir. Tabloları görüntülemek için lütfen masaüstü bir cihaz kullanarak giriş yapınız.
| Boiler Model | Maximum Thermal Power | Natural Gas | Diesel | Dual Fuel (Natural Gas – Diesel) | |
|---|---|---|---|---|---|
| kW | kcal/h | Model | Model | Model | |
| INSUZPR350 | 407 | 350.000 | FBR GAS XP60TC EVO FBR GAS XP60/2 TC EVO FBR GAS XP60/M TC EVO |
FBR FGP 50/2 TC EVO-3 FBR FGP 50/M TC EVO |
FBR К 4/2 TC EVO2 |
| INSUZ PR 400 | 465 | 400.000 | FBR GAS XP60TC EVO FBR GAS XP60/2 TC EVO FBR GAS XP60/M TC EVO |
FBR FGP 50/2 TC EVO-3 FBR FGP 50/M TC EVO |
FBR К 4/2 TC EVO2 |
| INSUZ PR 450 | 523 | 450.000 | FBR GAS XP60TC EVO FBR GAS XP60/2 TC EVO FBR GAS XP60/M TC EVO |
FBR FGP 50/2 TC EVO-3 FBR FGP 50/M TC EVO |
FBR К Х5/2 TC FBR К X 5/M/2 TC EL |
| INSUZ PR 500 | 581 | 500.000 | FBR GAS XP60TC EVO FBR GAS XP60/2 TC EVO FBR GAS XP60/M TC EVO |
FBR FGP 50/2 TC EVO-3 FBR FGP 50/M TC EVO |
FBR КХ5/2 TC FBR К X 5/M/2 TC EL |
| INSUZ PR 600 | 698 | 600.000 | FBR GAS XP80/2 TC FBR GAS XP80/M CETC |
FBR FGP 75/2 TC FBR FGP 75/M TC |
FBR К Х5/2 TC FBR К X 5/M/2 TC EL |
| INSUZ PR 700 | 814 | 700.000 | FBR GAS P100/2 EVO FBR GAS P100/M TC EVO |
FBR FGP 75/2 TC FBR FGP 75/M TC |
FBR К Х6/2 EVO TL FBR К Х6/М EVO TL |
| INSUZ PR 800 | 930 | 800.000 | FBR GAS P100/2 EVO FBR GAS P100/M TC EVO |
FBR FGP 100/2 TC EVO FBR FGP 100/M TC EVO |
FBR К Х6/2 EVO TL FBR К Х6/М EVO TL |
❗ Brülör eşleşme tabloları yalnızca masaüstü cihazlarda görüntülenebilmektedir. Tabloları görüntülemek için lütfen masaüstü bir cihaz kullanarak giriş yapınız.
| Boiler Model | Maximum Thermal Power | Natural Gas | Diesel | Dual Fuel (Natural Gas – Diesel) | |
|---|---|---|---|---|---|
| kW | kcal/h | Model | Model | Model | |
| INSUZ PRS 1000 | 1162 | 1.000.000 | FBR GAS P130/2 TC EVO FBR GAS P130/M TCEVO |
FBR FGP 130/2 TC EVO FBR FGP 130/M TCEVO |
FBRК Х6/2 EVO TL FBR К Х6/М EVO TL |
| INSUZPRS 1250 | 1454 | 1.250.000 | FBR GAS P160/2 TC FBR GAS P160/M TC |
FBR FGP 160/2 TC FBR FGP 160/M TC |
FBRК Х7/2 TL FBR К Х7/М TL |
| INSUZ PRS 1500 | 1744 | 1.500.000 | FBR GAS P160/2 TC FBR GAS P160/M TC |
FBR FGP 190/3 TL FBR FGP 190/M TL |
FBR К 190/M TL EL |
| INSUZPRS 1750 | 2035 | 1.750.000 | FBR GAS P190/M TL | FBR FGP 190/3 TL FBR FGP 190/M TL |
FBR К 190/M TL EL |
| INSUZ PRS 2000 | 2326 | 2.000.000 | FBR GAS P250/M TL | FBR FGP 250/3 TL FBR FGP 250/M TL |
FBR К 250/M TL EL |
| INSUZ PRS 2500 | 2907 | 2.500.000 | FBR GAS P300/M TL | FBR FGP 350/3 TL FBR FGP 350/M TL |
FBR К 350/M TL |
| INSUZ PRS 3000 | 3488 | 3.000.000 | FBR GAS P450/M TL | FBR FGP 350/3 TL FBR FGP 350/M TL |
FBR К 350/M TL |
| INSUZ PRS 3500 | 4070 | 3.500.000 | FBR GAS P450/M TL | FBR FGP 450/3 TL FBR FGP 450/M TL |
FBR К 450/M TL |
| INSUZ PRS 4000 | 4651 | 4.000.000 | FBR GAS P550/M CE TL | FBR FGP 450/3 TL FBR FGP 450/M TL |
FBR К 550/M TL |
| INSUZ PRS 5000 | 5813 | 5.000.000 | FBR GAS P650/M CE TL | FBR FGP 650/M TL | FBR К 650/M TL |
❗ Brülör eşleşme tabloları yalnızca masaüstü cihazlarda görüntülenebilmektedir. Tabloları görüntülemek için lütfen masaüstü bir cihaz kullanarak giriş yapınız.
| Boiler Model | Steam | Natural Gas | Diesel | Dual Fuel (Natural Gas – Diesel) | |
|---|---|---|---|---|---|
| Kg/h | kW | Model | Model | Model | |
| INPAR 400 | 400 | 260 | FBR GAS X5 TC FBR GAS X5/2 TC FBR GAS Х5/М TC |
FBR G X5S TC FBR GX5.22TC FBR G X5/2 TC |
FBR К 4/2 TC EVO2 |
| INPAR1OOO | 1000 | 651 | FBR GAS ХР80/2 TC FBR GAS ХР80/М TC |
FBR FGP 75/2 TC FBR FGP 75/M TC |
FBR К Х5/2 TC FBR К X 5/M/2 TC EL |
| INPAR1600 | 1600 | 1042 | FBR GAS P100/2 TC EVO FBR GAS P100/M TC EVO |
FBR FGP 100/2 TC EVO FBR FGP 100/M TC EVO |
FBR К Х6/2 EVO TL FBR К Х6/М EVO TL |
| INPAR 2000 | 2000 | 1302 | FBR GAS P130/2 TC EVO FBR GAS P130/M TC EVO |
FBR FGP 130/2 TC EVO FBR FGP 130/M TC EVO |
FBR К Х7/2 TL FBR К Х7/М TL |
| INPAR2400 | 2400 | 1563 | FBR GAS P160/2 TC FBR GAS P160/M TC |
FBR FGP 160/2 TC FBR FGP 160/M TC |
FBR К Х7/2 TL FBR К Х7/М TL |
| INPAR 2800 | 2800 | 1823 | FBR GAS P190/M TL | FBR FGP 190/3 TL FBR FGP 190/M TL |
FBR К 190/M TL EL |
| INPAR3200 | 3200 | 2084 | FBR GAS P190/M TL | FBR FGP 190/3 TL FBR FGP 190/M TL |
FBR К 190/M TL EL |
| INPAR3600 | 3600 | 2344 | FBR GAS P250/M TL | FBR FGP 250/3 TL FBR FGP 250/M TL |
FBR К 250/M TL EL |
| INPAR 4000 | 4000 | 2605 | FBR GAS P250/M TL | FBR FGP 250/3 TL FBR FGP 250/M TL |
FBR К 250/M TL EL |
| INPAR 5000 | 5000 | 3256 | FBR GAS P350/M TL | FBR FGP 350/3 TL FBR FGP 350/M TL |
FBR К 350/M TL |
| INPAR 6000 | 6000 | 3907 | FBR GAS P450/M TL | FBR FGP 450/3 TL FBR FGP 450/M TL |
FBR К 450/M TL |
FBR Burner-Compatible Boiler Selection Tables
The FBR burner, with natural gas, diesel, and dual-fuel burner models, is designed to be compatible with PR, PRS, and PAR series boilers. The tables above show the technically compatible FBR burner options for each boiler type. The FBR burner-boiler compatibility is based on manufacturer data, allowing for direct selection without the need for additional calculations.
Technical Compatibility and Performance Criteria
FBR burners offer high efficiency and low emissions when used in systems working with various fuel types. The natural gas FBR burner is commonly used in hot water and steam boilers, while the diesel and dual-fuel FBR burner models provide flexible operational conditions. When selecting a FBR burner, factors such as nominal capacity, modulation range, and operating pressure must be considered.
Energy Efficiency and System Compatibility
The modulating FBR burners can automatically adjust their capacity according to system demands. This helps save energy while also extending the lifespan of the boiler. The FBR burner matches in the tables include models that provide stable performance under different operating conditions.
Burner-Boiler Matching
The selection tables show the recommended FBR natural gas burner, FBR diesel burner, and FBR dual-fuel burner alternatives for each boiler model. When selecting a FBR burner, factors such as thermal capacity requirements, flue draft, combustion air supply, and installation area must also be considered. All necessary technical information is available in the manufacturer’s documentation.
Support and Technical Information
For further details or special projects, you can request technical support. Detailed product documentation and engineering calculations for the FBR burner are available on the official FBR burner manufacturer’s website. For the most suitable FBR burner solution based on the relevant boiler series, it is recommended to contact our expert team.