Below are the selection tables designed for INSUZ PR, PRS, and PAR series boilers, fully compatible with Gokce natural gas burners, diesel burners, and dual-fuel burner models. Each table clearly indicates the appropriate Gokce burner model for every boiler type, allowing for a quick and accurate burner-to-boiler match—no complex technical calculations required.
Gokce offers a wide range of industrial burner solutions including:
Natural gas burners
Diesel burners
Dual-fuel burners
These burners are ideal for a variety of applications such as hot water boilers, steam boilers, industrial ovens, and process heating systems.
Key features include:
Advanced modulation technology
High combustion efficiency
Low emission (Low NOx certified series available)
Easy integration with modern control systems
Founded in 1964, Gokce is one of Turkey’s leading industrial burner manufacturers.
Over 150 authorized service points across Turkey ensure fast and reliable after-sales support.
Burners are certified for international compliance and quality standards.
Each table provides:
The correct Gokce burner model for each INSUZ boiler
Burner type (gas, oil, dual-fuel)
Burner capacity and modulation range
Compatibility without the need for additional engineering calculations
Ideal for small to medium-scale heating projects. Compatible with Gokce modulating gas burners.
Mid to large-scale applications where diesel or dual-fuel Gokce burners are commonly used for flexibility and robustness.
Designed for process and industrial use, where Gokce high-capacity dual-fuel burners ensure stable and efficient operation.
✅ Fast and precise burner matching using pre-calculated compatibility tables
✅ Higher combustion efficiency with low fuel consumption
✅ Reduced emissions with Low NOx compliant burners
✅ Flexible fuel options: natural gas, diesel, or both
✅ Comprehensive technical support from both manufacturers
Visit the official Gokce website to access technical datasheets, burner specifications, and performance charts.
Download the INSUZ–Gokce burner compatibility tables directly from the INSUZ Boiler website.
For project-specific burner recommendations, quote requests, or technical consultation, please get in touch with our engineering team. We’re happy to support your heating system design from planning to commissioning.
❗Brülör eşleşme tabloları yalnızca masaüstü cihazlarda görüntülenebilmektedir. Tabloları görüntülemek için lütfen masaüstü bir cihaz kullanarak giriş yapınız.
Boiler Model | Maximum Thermal Power | Natural Gas | Liquid Fuel | Dual Fuel (Natural Gas – Diesel) | |
---|---|---|---|---|---|
kW | kcal/hour | Model | Model | Model | |
INSUZ PR 350 | 407 | 350 | Gökçe C45 S Gökçe C 55 S |
Gökçe T45 Gökçe T80 |
Gökçe C(L)55 Gökçe C(L) 80 |
INSUZ PR 400 | 465 | 400 | Gökçe C 45 S Gökçe C 55 S |
Gökçe T45 Gökçe T80 |
Gökçe C(L)55 Gökçe C(L) 80 |
INSUZ PR 450 | 523 | 450 | Gökçe C55 S Gökçe C 80 S |
Gökçe T45 Gökçe T80 |
Gökçe C(L)55 Gökçe C(L) 80 |
INSUZ PR 500 | 581 | 500 | Gökçe C80 S Gökçe C 80 AGP |
Gökçe T80 /2 Gökçe T135 |
Gökçe C(L) 80 Gökçe C(L) 80 AGP Gökçe C(L) 80 M AGP |
INSUZ PR 600 | 698 | 600 | Gökçe C 80 AGP Gökçe C 135 cS Gökçe C 135 bS Gökçe C 135 aS Gökçe C 135 AGP |
Gökçe T80 Gökçe T135 |
Gökçe C(L) 80 Gökçe C(L) 80 AGP Gökçe C(L) 80 M AGP |
INSUZ PR 700 | 814 | 700 | Gökçe C 135 cS Gökçe C 135 bS Gökçe C 135aS Gökçe C 135 AGP |
Gökçe T80 Gökçe T135 /2 |
Gökçe C(L) 80 AGP Gökçe C(L) 135bS Gökçe C(L) 135 AGP Gökçe C(L) 135 M AGP |
INSUZ PR 800 | 930 | 800 | Gökçe C 135 cS Gökçe C 135 bS Gökçe C 135aS Gökçe C 135 AGP Gökçe TG 200 AGP |
Gökçe T135 Gökçe T200 Gökçe T200/2 |
Gökçe C(L) 135 bS Gökçe C(L) 135 AGP Gökçe TG(L) 200 AGP Gökçe TG(L) 200/MAGP |
❗ Brülör eşleşme tabloları yalnızca masaüstü cihazlarda görüntülenebilmektedir. Tabloları görüntülemek için lütfen masaüstü bir cihaz kullanarak giriş yapınız.
Boiler Model | Maximum Thermal Power | Natural Gas | Liquid Fuel | Dual Fuel (Natural Gas – Diesel) | |
---|---|---|---|---|---|
kW | kcal/hour | Model | Model | Model | |
INSUZ PRS1000 | 1162 | 1.000.000 | GokceC 135 bS Gokce C 135 AGP Gokce TG 200 AGP |
GokceT 135 Gokce T 135/2 Gokce T 200 Gokce T 200/2 |
GokceC (L) 135 bS Gokce C (L) 135/2 bS Gokce C (L) 135 AGP Gokce C (L) 135/MAGP Gokce TG (L) 200 AGP Gokce TG (L) 200/M AGP |
INSUZ PRS1250 | 1454 | 1.250.000 | GokceTG 200 AGP Gokce TG 250 AGP |
GokceT 200 Gokce T 200/2 Gokce DLUZ 200 Gokce DLUZ 200/2 |
GokceTG (L) 200 AGP Gokce TG (L) 200/M AGP Gokce TG (L) 250 AGP Gokce TG (L)250/M AGP |
INSUZ PRS1500 | 1744 | 1.500.000 | GokceTG 200 AGP Gokce TG 250 AGP |
GokceT 200 Gokce T 200/2 Gokce DLUZ 200 Gokce DLUZ 200/2 |
GokceTG (L) 200 AGP Gokce TG (L) 200/M AGP Gokce TG (L) 250 AGP Gokce TG (L)250/M AGP |
INSUZ PRS1750 | 2035 | 1.750.000 | GokceTG 250 AGP Gokce TG 400 a AGP |
GokceT 200 Gokce T 200/2 Gokce DLUZ 200 Gokce DLUZ 200/2 |
GokceTG (L) 250 AGP Gokce TG (L) 250/M AGP Gokce TG (L) 400 b AGP Gokce TG (L) 400/M b AGP |
INSUZ PRS2000 | 2326 | 2.000.000 | GokceTG 250 AGP Gokce TG 400 a AGP |
GokceDLUZ 200 Gokce DLUZ 200/2 Gokce TO 400 Gokce TO 400/M |
GokceTG (L) 250 AGP Gokce TG (L) 250/M AGP Gokce TG (L) 400 b AGP Gokce TG (L) 400/M b AGP |
INSUZ PRS2500 | 2907 | 2.500.000 | GokceTG 400 a AGP Gokce TG 400 b AGP |
GokceTO 400 Gokce TO 400/M Gokce TO 500 Gokce TO 500/M |
GokceTG (L) 400 b AGP Gokce TG (L)400/M b AGP Gokce TG (L) 500 b AGP Gokce TG (L) 500/M b AGP |
INSUZ PRS3000 | 3488 | 3.000.000 | GokceTG 400 b AGP Gokce TG 500 b AGP |
GokceTO 400 Gokce TO 400/M Gokce TO 500 Gokce TO 500/M |
GokceTG (L) 400 b AGP Gokce TG (L)400/M b AGP Gokce TG (L) 500 b AGP Gokce TG (L) 500/M b AGP |
INSUZ PRS3500 | 4070 | 3.500.000 | GokceTG 500 b AGP Gokce TG 803 a AGP |
GokceTO 400 Gokce TO 400/M Gokce TO 500 Gokce TO 500/M |
GokceTG (L) 500 b AGP Gokce TG (L)500/M b AGP Gokce TG (L) 803 a AGP Gokce TG (L) 803/M a AGP |
INSUZ PRS4000 | 4651 | 4.000.000 | GokceTG 803 a AGP Gokce TG 803 b AGP |
GokceTO 500 Gokce TO 500/M Gokce TO 803 a Gokce TO 803/M a |
GokceTG (L) 803 a AGP Gokce TG (L)803/M a AGP Gokce TG (L) 803 b AGP Gokce TG (L) 803/M b AGP |
INSUZ PRS5000 | 5813 | 5.000.000 | GokceTG 803 a AGP Gokce TG 803 b AGP |
GokceTO 803 a Gokce TO 803/M a Gokce TO 803 b Gokce TO 803/M b |
GokceTG (L) 803 a AGP Gokce TG (L)803/M a AGP Gokce TG (L) 803 b AGP Gokce TG (L) 803/M b AGP |
❗ Brülör eşleşme tabloları yalnızca masaüstü cihazlarda görüntülenebilmektedir. Tabloları görüntülemek için lütfen masaüstü bir cihaz kullanarak giriş yapınız.
Boiler Model | Steam Boiler Capacity | Natural Gas | Liquid Fuel | Dual Fuel (Natural Gas – Diesel) | |
---|---|---|---|---|---|
Kg/h | kW | Model | Model | Model | |
INPAR400 | 400 | 260 | GokceTG 30 | GokceDLÜ 25 Gokce T 45 Gokce T 45 /2 |
GokceC (L)55 S Gokce C (L)55/2 S Gokce C (L)80 S Gokce C (L)80/2 S |
INPAR1000 | 1000 | 651 | GokceC 80 S Gokce C 80 AGP |
GokceT 80 Gokce T 80 /2 Gokce T 135 Gokce T 135 /2 |
GokceC (L)80 S Gokce C (L)80/2 S Gokce C (L)80 AGP Gokce C (L)80/M AGP |
INPAR1600 | 1600 | 1042 | GokceC 135 cS Gokce C 135 bS Gokce C 135 AGP Gokce TG 200 AGP |
GokceT 135 Gokce T 135/2 Gokce T 200 Gokce T 200/2 |
GokceC (L)135 bS Gokce C (L)135/2b S Gokce C (L)135 AGP Gokce C (L)135/M AGP Gokce TG (L) 200 AGP Gokce TG (L) 200/M AGP |
INPAR2000 | 2000 | 1302 | GokceTG 200 AGP Gokce TG 250 AGP |
GokceT 135 Gokce T 135/2 Gokce T 200 Gokce T 200/2 |
GokceTG (L) 200 AGP Gokce TG (L) 200/M AGP Gokce TG (L) 250 AGP Gokce TG (L)250/M AGP |
INPAR2400 | 2400 | 1563 | GokceTG 200 AGP Gokce TG 250 AGP |
Gokce T 200 Gokce T 200/2 Gokce DLUZ 200 Gokce DLUZ 200/2 |
GokceTG (L) 200 AGP Gokce TG (L) 200/M AGP Gokce TG (L) 250 AGP Gokce TG (L)250/M AGP |
INPAR2800 | 2800 | 1823 | GokceTG 250 AGP Gokce TG 400 a AGP |
GokceT 200 Gokce T 200/2 Gokce DLUZ 200 Gokce DLUZ 200/2 |
GokceTG (L) 250 AGP Gokce TG (L) 250/M AGP Gokce TG (L) 400 b AGP Gokce TG (L)400/M b AGP |
INPAR3200 | 3200 | 2084 | GokceTG 250 AGP Gokce TG 400 a AGP |
GokceT 200 Gokce T 200/2 Gokce DLUZ 200 Gokce DLUZ 200/2 |
GokceTG (L) 250 AGP Gokce TG (L) 250/M AGP Gokce TG (L) 400 b AGP Gokce TG (L)400/M b AGP |
INPAR3600 | 3600 | 2344 | GokceTG 250 AGP Gokce TG 400 a AGP |
GokceDLUZ 200 Gokce DLUZ 200/2 Gokce TO 400 Gokce TO 400/M |
GokceTG (L) 250 AGP Gokce TG (L) 250/M AGP Gokce TG (L) 400 b AGP Gokce TG (L)400/M b AGP |
INPAR4000 | 4000 | 2605 | GokceTG 250 AGP Gokce TG 400 a AGP |
GokceDLUZ 200 Gokce DLUZ 200/2 Gokce TO 400 Gokce TO 400/M |
GokceTG (L) 250 AGP Gokce TG (L) 250/M AGP Gokce TG (L) 400 b AGP Gokce TG (L)400/M b AGP |
INPAR5000 | 5000 | 3256 | GokceTG 400 b AGP Gokce TG 500 b AGP |
GokceTO 400 Gokce TO 400/M Gokce TO 500 Gokce TO 500/M |
GokceTG (L) 400 b AGP Gokce TG (L) 400/M b AGP Gokce TG (L) 500 b AGP Gokce TG(L) 500/M b AGP |
INPAR6000 | 6000 | 3907 | GokceTG 500 b AGP Gokce TG 803 a AGP |
GokceTO 400 Gokce TO 400/M Gokce TO 500 Gokce TO 500/M |
GokceTG (L) 500 b AGP Gokce TG (L) 500/M b AGP Gokce TG (L) 803 a AGP Gokce TG(L) 803/M A AGP |
Gokce natural gas burners, diesel burners, and dual-fuel (gas – diesel) burners
Gokce burners with natural gas, diesel, and dual-fuel options are used in a wide range of applications, from industrial facilities to hot water boilers. These burners are known for their high efficiency and low emissions. Natural gas burners are frequently preferred in applications such as industrial furnaces, steam boilers, and hot water boilers. Additionally, diesel and dual-fuel burners provide flexibility in fuel usage and offer advantages across various industries.
Gokce burners offer high energy efficiency between gas and liquid fuel burners, while their automatic ignition features reduce the workload for users. Modulating burner technology ensures that the system operates more efficiently and optimizes energy consumption. Low-emission burners offer an environmentally friendly solution, increasing energy efficiency, and burner capacity selection can be customized for specific projects.
Industrial burners are compatible with different types of boilers and provide high performance, especially in large-capacity systems. The natural gas, diesel, and dual-fuel burners developed by Gokce work in perfect harmony with various boilers. This makes burner selection easier for each project and allows for the installation of more durable and efficient systems.
Another important factor in burner selection is choosing a burner with high efficiency and correct technical specifications. Gokce burners are environmentally friendly with low emission values and provide maximum efficiency, resulting in energy savings. Burners integrated into boiler systems operate at high performance while reducing energy costs.
The compatible use of Gokce burners in systems such as industrial furnaces, steam boilers, and hot water boilers ensures efficient and safe operation. By reviewing the technical specifications and installation details of the burners, you can select the most suitable model.